ORVALDI 6000/10000RT ON-LINE (12,18,20,24 and 30kVA - parallel, redundancy)

Rack/Tower design - only 2U height  6kVA and 3U 10kVA
True On-line Double Conversion Topology
Advanced Digital Control
Technology N+1
Power Scaleable Parallel Redundancy
Active Harmonic Current Control
Energy-efficient UPS Normal/ECO Mode Operation
Personalization & Intelligent Self-diagnostic
Manifold Interfaces
Hot-Swappable Battery
Galvanic Isolation
External Battery module 3U


Application :  Application : Data center, servers, networks, industrial and medical equipment.
Characteristic

 

Using our field-proven Digital Signal Processor (DSP) with SMD techniques, the ORVALDI 6000/10000 series UPS achieves higher reliability and greater immunity from Utility power problems to the connected load. The front panel clearly communicates all major system parameters, system status and full self fault diagnosis for easy servicing. Utilizing our unique patented inverter control technology, the ORVALDI 6000/10000 series achieves N+1 power scaleable parallel redundant UPS system without additional parts.

 

Simple Parallel Installation

For increasing power capacity or making redundant system, the ORVALDI 6000/10000 series can be installed for operation in parallel. Simply connecting the parallel control lines through RJ-45 connector on the rear panel with CAN-bus communication is established to all units. The maximum parallel operation configuration is 4 units.

 

Full-time Digital Signal Processor Control

The full-time DSP control system inside ORVALDI 6000/10000 series provides both the pure sine wave at the output and the perfect sine wave to input current. The advanced DSP technology also provides user-friendly operation and access to system information and unit personalization via the front panel.

 

True Double Conversation On-line Technology

Completely re-generating the clean and safe power to correct the power disturbances in the Utility power source, the Voltage Frequency Independent (VFI) working mode of the ORVALDI 6000/10000 series complies with the exacting EN60240-3.

 

High Input Power Factor and Low Current THD 

The ORVALDI 6000/10000 series provides a “clean” rectifier connecting to the Utility power. It meets today’s industry standard for energy saving and low reflected harmonic pollution to the Utility and achieves up to 0.99 at Input Power Factor as well as <5% at Input Current THD.

 

Energy-efficient UPS

The AC to AC efficiency of the UPS may reach up to 91% at 25% load and better with larger loadings and normal VFI operation. Using the ECO mode efficiencies up to 98% can be achieved. 

 

Dual Input Loops

The ORVALDI 6000/10000 series provides single input connections as standard; however, separate input terminals for the bypass and rectifier can be provided as an option in the Tower series. Additionally, configuring the 3-phase input & 1-phase output systems at the site are available but they must be ordered as dual input versions.

 

Programmable Frequency Converter

Through front keypad configuration, you may reprogram the ORVALDI 6000/10000 Tower series to be a Frequency Converter for either 50Hz or 60Hz.  To set the Convertible series to be a frequency converter shall be required by a qualified technician.

 

LCD/LED Mimic Panel

A concise LCD/LED display provides real-time status and readings such as operation modes, AC voltage, frequency, battery voltage, load level, inner temperature, etc. A full size microprocessor-based graphical LCD display provides advanced monitoring functions that greatly enhance user friendly operation. 

 

Easy-to-Set User Personalization

Through the LCD front panel, you may easily change the parameters and settings built-in the DSP controllers, such as UPS operation modes, output voltage settings, fine adjustment, synchronization frequency windows (for use with generators), bypass voltage tolerances and buzzer alarm status.

 

Intelligent Self-Diagnostics

The self-diagnostics inside the DSP assists the service engineers to pinpoint system faults rapidly enabling fast repair times. The ORVALDI 6000/10000 series provides a feature to go to service mode and check each device step by step, then display the result on the LCD display. 

 

Silent Fan Control

The ORVALDI 6000 / 10000 series employs air forced cooling by internally mounted fans with speed control according to load percentage. This means low audible noise levels so is suitable for most environments including offices and hospitals.

 

Optional EPO Function

The ORVALDI 6000/10000 series enables user to shutdown the UPS in an emergency situation.

 

Smart ECO Mode

In ECO operation mode, the ORVALDI 6000/10000 series normally supplies power to load by Bypass Utility. It will automatically transfer to inverter supply with Smart Active Control, if Bypass Utility is out of tolerance.

 

Maintenance Manual Bypass

It ensures continuous supply of power to the critical load during service or periodical maintenance of the UPS system. The Manual Bypass Switch built is electrically interlocked with the inverter to provide safe operation. The Maintenance Manual Bypass is built onto the rear panel of the UPS as standard for the Tower series and it is built onto a separate Rack Mount cabinet with the galvanic isolation transformer(GTM-WS) or RacPDU-230 as optional for the Convertible series.

 

For ORVALDI 6000 Convertible UPS Only

Model 

Description

Dimension(WxDxH)mm

Net Weight

GTM-WS

Galvanic Isolation transformer & Maintenance Bypass Switch

440*88*660

42kgs

GTM-WOS

Galvanic Isolation Transformer

440*88*660

41kgs

RacPDU-230

Rack Power Distribution Unit

326*88*100

3.5kgs

TowPDU-260

Parallel Distribution Box(60A) for 2 UPS

265*240*93.2

5kgs

TowPDU-2120

Parallel Distribution Box(120A) for 4 UPS

265*415*93.2

9kgs

 

 

Optional Galvanic Isolation Transformer

The galvanic isolation transformer offered may provide not only a complete isolation between input and output, but also various secondary voltages, such as 220/230/240Vac, 208Vac/120Vac and 240Vac/120Vac.

 

Advanced Battery Discharge Management

The ORVALDI 6000/10000 series automatically manages the end of discharge voltage according to load. The ABDM function prevents deep-discharge of the built-in battery during a power failure.

 

Cold Start Function

Users can turn on the UPS without connecting to the Utility power for starting applications.

 

Power Range and Runtime Scalability

The ORVALDI 6000/10000 series provides excellent return on investment. The system is fully modular allowing you to increase the overall power output, battery runtime and redundancy as your system grows. It is important however that you design your electrical installation to support your needs. Our worldwide network of Distributors can assist you in designing the electrical requirements.

 

Variety of Customer Options Slots

The UPS also provides two additional Customer Option Communication slots in additional to the standard RS232 port.  All communication cards are designed to provide simple installation as electrical connections are made through a 26-pin edge card connector. The first RS232 port on the rear panel will remain active, even though optional communication card(s) are installed.  

 

Communication Capability

The ORVALDI 6000/10000 series are all shipped with monitoring/shutdown software as standard. The software allows not only the control of the UPS and graceful shutdown when the Utility Power fails, but also allows the user to:

l      Remotely test the major operating functions of the UPS.

l      Communicate via SNMP/WEB card.

l      Access UPS functions via the WEB.

 

Optional External Battery Charger

With its isolation conversion technology plus precision control, the optional charger can be installed in parallel operation up to 4 units. The specifications are as follows:  

 

AC Input Range:

100-280Vac, 45-65Hz

Maximum Power Output:

1000W, continuously

Operation Mode:

Constant Voltage with Current Limitation

Maximum Parallel Units:

Up to 4 units

Protections:

Over-temperature, Over-voltage, Against Output Short-Circuit & Isolated devices for Opposite Polarity Connection.

Mounting:

Mounted on the rear of the UPS or the wall.

Dimension(WxDxH)

166 x 282 x 86mm

Net Weight

3.2kgs

 

Matching Battery Cabinet Connectivity

Standard matching battery cabinets are available to easily extend the UPS runtime to several hours.   


Super Compact Convertible Design

With most compact 2U design, the UPS occupies less space in the 19” rack cabinet, or in the 21” rack cabinet with the optional 21” Rack accessories, which may save your initial setup cost.   The convertible design also offers a flexible form factor enabling integration into a wide variety of environment and minimizing a great stock pressure from distributors/dealers.

Technical data

 
INPUT
 
Voltage
160 ~ 280Vac*
Frequency
45 ~ 65 Hz
Phase / Wire
Single, Line + Neutral + Ground
Power Factor
Up To 0.99 at 100% Linear Load
Current THD
<5% at 100% Linear Load
OUTPUT
 
Voltage
200/208/220/230/240Vac Selectable (208/120Vac Optional)
Voltage Adjustment
Nominal +1%, +2%, +3%, -1%, -2% or -3%
Voltage Regulation
±2%
Capacity
6000VA/4200W                               10000VA/7000W 
Rated Power Factor
0.7 lagging
Wave From
Sine Wave, THD <3% (no load to full load)
Frequency Stability
±0.2% On Inverter Free-Running Mode
Frequency Regulation
+/-1Hz, +/-3Hz (programmable by user)
Transfer Time
0 ms
Crest Factor
3:1 acceptable
Efficiency(AC to AC, Normal)
Up to 91%
Efficiency(AC to AC, ECO)
Up to 98%
Autonomy(run time at full load)
>8 min.
DC Start
Yes
BATTERY
 
Type
Sealed Lead Acid Maintenance Free
Battery
7AH                                                             9AH
Quantity
20pcs in single external cabinat
Voltage
240Vdc
Recharge Time
4 Hours to 90%
DISPLAY
 
Status on LED + LCD
Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, Transferring with Interruption, & UPS Fault.
Readings on LCD
Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, & Inner Temperature.
Self-Diagnostics
Upon Power-on & Front Panel Setting  
PROTECTION
 
Overload ( with simulated thermal tripping I-T curve)
Inverter Supply: 105% ~ 150% for 160 seconds ~ 2 cycles before switching to bypass
Bypass Supply: 105% ~ 200% for 500 seconds ~ 8 cycles before stopping supply load 
Short Circuit
Switch Off Immediately
Overheat
AC mode: Switch to Bypass,
Backup mode: Switch off the UPS
Battery Low
Alarm and Switch Off
Noise Suppression
Complies with EN50091-2
Spike Suppression
Complies with EN61000-4-5
ALARMS
 
Audible and Visual
Line Failure, Battery Low, Transfer to Bypass, System Fault Condition
PHYSICAL
 
UPS Dimensions (W x D x H)mm
440x88x667 2U        (Power Module Only)        440x176x667 3U
Battery module BB6KRT0(20pcs 12V/7AH)
440x176x667(3U)
Battery module BB6KRT1(20pcs 12V/9AH)
440x176x667(3U)
Input & Output Connection
Hardwire
External Battery Connection
Plug-in & Play
Net Weight kgs
24(UPS Module)
Battery Bank Net Weight
 
 
 BB6KRT0 w/o bat./with bat.
13Kgs/47kgs
 BB6KRT1 w/o bat./with bat.
13Kgs/58kgs
 
 
ENVIRONMENT 
 
Operating Temperature
0 C to 40 C
Temperature Warning
The battery design life is based on a temperature of 25 C. Ambient temperature above this range will reduce battery life.
Altitude
0~2000m up to 40 C, 3000m up to 35 C
Humidity
90% RH Maximum, Non-Condensing
Noise
<50dB (at 1 meter)
COMPUTER INTERFACE 
 
Interface Type
Standard RS232 Interface
Communication Slots
2nd RS232 & EPO***, USB & EPO***, RS485 & EPO***, Relay Contact & EPO, SNMP/WEB Card, etc.
SAFETY CONFORMANCE 
 
Quality Assurance
ISO9001 Certified Company
Safety Standard
EN50091-1, UL1778
EMC Standard
EN50091-2, EN61000-3-2, EN61000-3-3,
FCC Class A
Marks
CE, UL