language version: Czech English Estonian Finnish Franch German Latvian Lithuanian Polish Romanian Russian Slovak Ukrainian

ORVALDI PRODUCTS:
 

 
 



Product catalog : Data center
ORVALDI 6000/10000 ON-LINE

  • True On-line Double Conversion Topology
  • Advanced Digital Control Technology
  • N+1 Power Scaleable Parallel Redundancy
  • Active Harmonic Current Control
  • Energy-efficient UPS
  • Normal/ECO Mode Operation
  • Personalization & Intelligent Self-diagnostic
  • Manifold Interfaces
  • Hot-Swappable Battery
  • Galvanic Isolation
  • External Battery Cabinet & Charger

Application : Data center, servers, networks, industrial and medical equipment.
Characteristic

ORVALDI 6000 ON-LINE Parallel Redundancy

1p is ORVALDI 6000 ON-LINE = 6 kVA (4200W)
2p is
ORVALDI 6000 ON-LINE = 12 kVA (8400W)
working together, Parallel
3p is
ORVALDI 6000 ON-LINE = 18 kVA (12600W)
working together, Parallel
4p is ORVALDI 6000 ON-LINE = 24 kVA (16800W) working together, Parallel

or in 3 phase
3pis ORVALDI 6000 ON-LINE = 18 kVA schema 1/1 or 3/1

1p is ORVALDI 10000 ON-LINE = 10 kVA (7000W)
2p is ORVALDI 10000 ON-LINE = 20 kVA (14000W) working together, Parallel
3p is
ORVALDI 10000 ON-LINE = 30 kVA (21000W)
working together, Parallel

or in 3 phase
3pis ORVALDI 10000 ON-LINE = 30 kVA schema 1/1 or 3/1

Using a field-proven Digital Signal Processor(DSP), the ORVALDI 6000/10000 on-line series UPS performs as a truly user-friendly unit for easy operation and access to system information and unit personalization. With patent-owned bi-directional control technology, the ORVALDI 6000 on-line series achieves N+1 power scaleable parallel redundant UPS system without additional parts. It is an ideal power protection solution for Servers, Networks, Storage, Telecommunications, Industrial Equipment as well as Medical Diagnostic equipment.
Parallel/Redundancy/Load Shaning/N+1 enables you to increase power capacity or make redundant system easily. Simply connecting the parallel control lines with CAN communication to all units, the UPS can operate in parallel mode without additional parts required. The maximum parallel operation may reach up to 4 unite.
Dual Input Loops design provides a dual input loop one for rectifier end the other for Bypass.
Constant Voltage Constant Frequency can be programmed through front keypad configuration to a frequency converter for either 50Hz or 60Hz.
An easy LCD/LED display provides real power status such as input voltage, output voltage, battery voltage, battery level, bad level, input/output frequency, temperature of inner cabinet, error code, UPS status, etc. A full-size graphical LCD display may provide advanced monitoring functions that greatly enhances friendly operating interface.
Smart Fan Speed Control employs air forced cooling by internally mounted fans according to bad percentage.
Optional EPO Function enables user to shutdown the UPS in an emergency situation.
In Real ECO(Economic) operation mode, the power supplied to bad 5 through the Static Switch normally. It will automatically transfer to inverter supply, if bypass Utility/Mains AC is out of tolerance.
Variety of Customer Options Slots offered is to enable user for field installation. All communication cards are designed to provide simple installation where electrical connections are made through a 26.pin edge card connector.
Standard Matching Battery Cabinets are available to easily extend the UPS runtime to several hours.
The Intelligent self-diagnostics inside the DSP may help service engineers to check out failure points rapidly.
Automatic and Manuel Bypass ensures continuous supply of power to the critical bad in the event of electronic failure, overload, overheat or scheduled maintenance.

Technical data

Model
ORVALDI 6000 / 10000 ON-LINE
INPUT

Voltage Window

160— 280 Vac

Frequency
45, 65Hz

Phase / Wire

Single, Line + Neutral + Ground

Power Factor

Up to 0.99 at 100% Linear Load

Current THD

<5% at 100% Linear Load

OUTPUT

Voltage Window

220 / 230/ 240 Vac Selectable (208 / 120 Vac optional)

Voltage Adjustment

±0%; ±1%; ±2%; ±3%

Voltage Regulation

±2%
Capacity

6000 VA/ 4200W         10000 VA/ 7000W

Rated Power Factor

0.7 Lagging

Wave Form

Sine Wave, THD <4% (no bad to full bad)

Frequency Stability

±0,2% (Free Running)

Frequency Regulation

±1% ±3%

Transfer Time

Oms

Crest Factor

3:1

Efficiency (AC to AC, Normal)

90%

Efficiency (AC to AC, ECO)

98%
Autonomy
8 min.
DC Start
Yes
BATTERY
Type

Sealed Lead Acid Maintenance Free 12V! 7Ah                      9Ah

Quantity
20pcs
Voltage
240V DC

Recharge Time

4 hours to 90%

Supp Charger

Optional 1000W isolated charger

DISPLAY
LED + LCD

Utility, Battery, nyerter, Bypass, Self-Test, Oyerboad Load / BaUery Leyel and Fault Conditions

Self-Diagnostics

Upon Power-on, Front Panel Setting S Software Control

ALARMS

Audible and Visual

Line Failure, Battery Low, Transfer to Bypass, System Fault Condution

PHYSICAL

Dimensions (W x D x H ) mm

290 x 645 x 748