ORVALDI 1000/2000/3000 RM/T ON-LINE

  • Double Conversion On-Line UPS
  • Tower/Rack Convertible Design
  • Urity Input Power Factor
  • Double Conversion On-Line Technology
  • Complete Protection Circuitry
  • Easy Swappable Battery
  • User Friendly Display
  • Matching Battery Cabinet
  • Smart Battery Management
  • Customer Options Slot
  • Optional Automatic & Manual Bypass

Application : Servers, Networks, Storage, Telecommunications, Medical Equipment
Characteristic

ORVALDI RM/T Series On-line UPS

The ORVALDI RM/T series, featured with industry-leading functionality, such as Unity Input Power Factor, Double Conversion On-Line Topology, Zero Transfer Time, Wide Input Voltage Range, Easy Swappable Battery, Smart Battery Management, is an ideal power protection solution for Servers, Networks, Storage, Telecommunications, Industrial Equipment as well as Medical Diagnostic equipment.

Tower/Rack Convertible design offers a flexible factor enabling integration into a wide variety of environments and minimizing a great stock pressure from distributors/dealers.

Unity Input Power Factor meets today's industry standard for energy saving and low reflected harmonic pollution to the Utility.

Double Conversion On-line Technology completely re-generates the Utility Power to correct the power disturbances in the Mains. The unit provides clean A.C. power 24 hours a day 365 days a year.

User Friendly Display clearly communicates all major system parameters and system status including load level, battery remaining and fault for easy service.

Matching Battery Cabinet is available to easily extend the UPS runtime to several hours. The battery cabinets are available with their own independent chargers to provide safe and fast recharging.

Easy Swappable Battery has a facility for the user to easily change the batteries at the end of useful service life.

The communication software bundled allows not only the control of the UPS and graceful shutdown when Utility fails, but also allows the user to remotely test the major operating functions of the UPS, communicate via SNMP/Web/Network adapter, access UPS functions viathe Web and also alert users via SMS messages against specific events.

Customer Options Slot allows further flexibility in network configuration. WEB/SNMP card, AS/400 card, USB card and True Relay card which may provide isolated contacts for industrial and remote alarm panel application are also available.

Optional Automatic & Manual Bypass ensures continuous supply of power to the critical load in the event of electronic failure, overload, overheat or scheduled maintenance. A matching Maintenance Bypass Switch Box(MTBS) is available.

Technical data

Buckup time for different capacity.
Capacity
ORVALDI 1000RM/T on-line
ORVALDI 2000RM/T on-line
ORVALDI 3000RM/T on-line
400VA/280W
31 min.
73 min.
96 min.
800VA/560W
11 min.
29 min.
72 min.
1000VA/700W
10 min.
20 min.
72 min.
1500VA/1050W

13 min.
18 min.
2000VA/1400W

11 min.
14 min.
2500VA/1750W


10 min.
3000VA/2100W


8 min.


MODEL
ORVALDI 1000RM/T on-line
ORVALDI 2000RM/T on-line
ORVALDI 3000RM/T on-line
INPUT
Voltage[Vac]
160 ~280
Frequency

50/60+/-5%(Auto Sensing)

Phase
Single

Input Power Factor

>0.98(Full Load)

OUTPUT
Voltage[Vca]
220/230/240
Capacity[VA/W]
1000VA/700W
2000VA/1400W
3000VA/2100W

Rated Power Factor

0.7
Wave Form

Sine Wave, THD<3%

Voltage Reg.

+/-2%

Transient Response

+/-4% pod 100% under full load, change and corrected within 60 ms

Frequency Stability

+/-0.5Hz Free Running

Synchronization

Slew Rate: 1Hz/Sek. Max. Synchronization Window+/-5%

Transfer Time
0 ms

Crest Factor

3:1

Efficiency (AC to AC)

>81%

Run-time P=MAX

>8 min.
>8 min.
>8 min.
DC Start
Yes
BATTERY
Type

Sealed lead acid maintenance free

Quantity
3 pis.
6 pis.
8 pis.
Voltage[Vda]
36
72
96

Recharge Time

8h do 90%

Supplementary Recharger

Optional 200W/500W Chargers for extended backup application

Palnel LED
LED

Utility, Battery Low, Inverter, Bypass, Test OK, Over Load Fault, Load/Battery Level, and Fault conditions

Self Diagnostics

Push Button (On demand)

PROTECTION
Overload

AC Mode:
1. <105% continuously.
2. 105% ~120% delay 50 s. before switching to bypass.
3. 120% ~150% delay 10 s. before switching to bypass.
4. >150% immediately switching to bypass.
Backup Mode:
Same delay time as AC mode, then completely shutdown.

Short Circuit

Hold Whole System

Overheat

Switch to Bypass

High Voltage Trip

Switch to Backaup Mode

Battery Low

Alarm and Switch Off

Noise Suppression

Complies with EN50091-2

Spike Suppression

Complies with EN610000-4-5

ALARMS

Audible and Visual

Line Failure, Battery Low, Transfer to Bypass, Over Load, System Fault Conditions.

PHISICAL

Dimensions

W x H x D [mm]

385x88x440
482x132x440
482x176x440

Outlets (ICE/Schuko)

3pis./1Sch.
3pis./2Sch.
Terminal/2Sch.
Net Weights [Kg]
16
29
39
ENVIRONMENT
Operating Temperature

0oC – 40oC

Humidity

90% RH Maximum, non-conditions

Noise

<45dB (at 1 meter)

INTERFEJS
Interface Type

Standard RS232/USB (Optional)

Protocol
Megatec
Software

UPSilion dla Novell NetWare, Windows 95/98, Windows NT, Windows ME, Windows 2000, Windows XP oraz Linux i Free BSD

SNMP Adaptability

AS/400 Card
Relay Card

Slot for SNMP Card (optional)

AS400 Card or True Interface Card provide, Utlity Failure, Battery Low, Bypass Active, UPS Shutdown functions.(optional)

SAFETY CONFORMANCE

Quality Assurance

ISO9001
Marks
CE, UL

EMC Standard

EN50091-2,EN61000-3-2,EN61000-3-3, FCC Lass A